360-209-4048

Home / Services / Commercial Water Heaters

Commercial water heater systems.

Commercial hot water demands are different: higher volume, continuous draw, and systems that can't afford downtime. We design, install, and service commercial water heater systems sized and configured for the job.

Multi-family, restaurant, commercial & light industrial  ·  Free estimates within 20 miles of Camas, WA
OR CCB 259728  ·  WA MAXWEPL768KO

A row of commercial water heaters in a mechanical room

Not just a bigger residential unit

Commercial systems require a different approach.

A commercial water heater installation isn't simply a larger version of a residential job. The demands are different, the equipment is different, the code requirements are different, and the consequences of an undersized or improperly installed system are felt immediately: cold showers, failed health inspections, or a flooded mechanical room.

We size systems based on actual demand calculations, not rule-of-thumb estimates. We design piping layouts that deliver consistent pressure and temperature to every point of use. And we install venting and combustion air systems that meet the specific requirements of commercial-grade equipment, because a commercial burner puts out significantly more heat than any residential unit, and the vent system has to handle it.

  • Load calculation firstWe calculate peak demand from fixture count, usage patterns, and recovery requirements, not estimates. A restaurant at lunch service and an apartment building at 7am have very different hot water profiles.
  • Permits are requiredCommercial water heater installations require permits and inspections in Washington and Oregon. We handle the permitting and schedule the inspections. It's not something to skip or work around.
  • Downtime has real costsA restaurant without hot water can't pass a health inspection. An apartment building without hot water has legal obligations to tenants. We plan installations to minimize downtime and have contingency approaches for critical replacements.
  • Redundancy is worth planning forA manifolded multi-unit system costs more upfront than a single large unit. It also means that when one unit fails, and eventually they all do, the building still has hot water while the repair happens.

What we do

Commercial water heater services.

New system installationFrom load calculation to final inspection, managed start to finish.
  • Hot water demand load calculation
  • Equipment sizing and selection
  • Permit application and coordination
  • Gas line sizing and extension
  • Commercial venting installation
  • Recirculation system design and installation
  • Final inspection and commissioning
Manifolded & linked systemsMulti-unit systems that keep hot water flowing if one unit goes offline.
  • Multi-unit manifold design
  • Demand-staged system configuration
  • Balanced supply and return headers
  • Individual unit isolation valves
  • Expansion tank sizing for the full system
  • Mixing valve installation for scald protection
  • System controls and aquastat setup
Replacement & upgradesLike-for-like replacements with minimal downtime, plus upgrades.
  • Emergency replacement with minimal downtime
  • Tank to tankless conversion
  • Capacity upgrades for growing demand
  • Efficiency upgrades (ENERGY STAR commercial units)
  • Single unit to manifolded system conversion
  • Recirculation pump replacement and upgrade
  • Code compliance updates on existing systems

Who we work with

Buildings and businesses we serve.

Multi-family

Apartment & condo buildings

Multi-unit residential buildings are among the most demanding hot water applications: high simultaneous draw, tenant expectations, and legal obligations around continuous supply. We design systems that meet peak demand without oversizing, and we plan for recovery time when multiple units draw at once.

Food service

Restaurants & commercial kitchens

High-temperature dishwasher requirements, hand-sink code compliance, and the reality that a health inspection doesn't wait. Restaurant hot water systems need careful sizing and reliable equipment. We understand what commercial kitchen demand looks like at peak service.

Fitness & hospitality

Gyms, hotels & lodging

Post-workout shower rushes, hotel check-in peaks, and continuous turnover create usage patterns that can overwhelm an undersized system. Manifolded tankless or staged tank systems are often the right answer, delivering consistent supply without the standby loss of a single large tank.

General commercial

Offices, retail & light industrial

Smaller commercial buildings often have simpler hot water needs, but they still need properly permitted, correctly vented commercial equipment, not residential units pressed into service beyond their rating. We right-size these systems and install them to code.

Before and after of a commercial water heater replacement by Maxwell Plumbing
Commercial water heater swap

In their words

What our neighbors say.

Good questions

Commercial water heater answers.

How do I know if I need a manifolded system or a single large unit?

It depends on your peak demand, your recovery requirements, and how much risk you're willing to carry. A single large commercial unit is simpler and less expensive upfront, but when it fails, you have no hot water until it's repaired. A manifolded system costs more to install but has redundancy built in: the remaining units keep running when one goes down. For any building where a hot water interruption creates significant operational or legal exposure, like restaurants, apartment buildings, and hotels, the manifolded approach is typically the right call. We'll help you model both options against your actual usage.

What venting is required for commercial gas water heaters?

Most commercial gas water heaters require Category III or Category IV venting: double-wall, positive-pressure stainless steel systems. This is completely different from the single-wall B-vent used on residential atmospheric equipment. The category is determined by the flue gas temperature and the static pressure the vent system operates under, both of which are higher in commercial power-burner equipment. Using the wrong vent material on a commercial unit is a code violation and a real safety hazard. We spec and install the correct vent system for the specific equipment being installed.

Do commercial water heater installations require a permit?

Yes. In both Washington and Oregon, commercial water heater installations require a mechanical or plumbing permit and a final inspection. This applies to new installations and to like-for-like replacements above a certain BTU threshold. We handle the permit application, coordinate the inspection schedule, and make sure the work passes. Unpermitted commercial equipment creates real liability exposure for building owners and can complicate insurance claims and future property transactions.

What is a mixing valve, and why does a commercial system need one?

Commercial water heaters are often set to store water at 140°F or higher to prevent Legionella bacteria growth in the tank. But 140°F water at the tap causes scalding, a particular concern in buildings with elderly residents, children, or high fixture turnover. An ASSE 1017-listed mixing valve (or thermostatic mixing valve) is installed at the point of distribution to blend hot water with cold down to a safe delivery temperature, typically 120°F, before it reaches the fixtures. Many commercial applications require these by code.

How is commercial hot water load actually calculated?

It starts with estimating peak simultaneous demand: how many fixtures are likely to be drawing hot water at the same time during the busiest period. From there we calculate the gallons per hour of recovery capacity needed to sustain that demand. The inputs include fixture count and type, usage patterns (a restaurant peaks differently than an apartment building), incoming water temperature, and desired delivery temperature. We use these to size both the storage capacity and the recovery rate of the system, which together determine the right equipment configuration.

What areas do you serve for commercial work?

SW Washington, including Camas, Vancouver, Washougal, and Ridgefield, and the Portland, Oregon metro. Estimates are free within 20 miles of Camas, WA. For larger commercial projects outside this area, call us and we'll talk through whether we can take on the scope.

Related reading: Test and review of the Essency EXR water heater

Maxwell Plumbing crest: a plumber waving a plunger from a Maxwell van, Serving the Pacific Northwest, Est. 2023

Free estimates within 20 miles of Camas.

Tell us about your building.

24/7 emergency service  ·  Based in Camas, WA  ·  OR CCB 259728  ·  WA MAXWEPL768KO